Question about Laars Lite 2 Heaters: 250,000BTU MV Heater

2 Answers

PILOT LIGHT WILL NOT LIGHT I HAVE A LAARS LITE 2 POOL HEATER OUTDOORS I,VE COME TO LIGHT IT AFTER THE WINTER AND I CANNOT GET THE PILOT LIGHT TO LIGHT THERES A SPARK FROM THE IGNITION AND I CAN HEAR ...

Ad

Question about H-series Electronic Gas Pool Heater H400

1 Answer

off after 2-3 seconds. Ck your burners for debris near the pilot, and any thing clogging the burner orfaces. You will need to reach into the orfaces to do this with a small bent wire or the like. Good

Ad

I have a '95 Bronco Eddie Bauer with the 5.8L in it. The Ac blows strong but only puts out air. I checked the r-134A and it reads full (reading 42psi). Any ideas what might be wrong? I WHOULD CHECK MY

Question about H Series Induced Draft Abg 100,000 Heater

1 Answer

...of the safetys and the same thing happens. Hayward model H1001D You may have spider webs in the gas orfaces. Pull the tray and unscrew the orfaces from the gas manifold then clean with a toothpic or ...

Question about H Series Induced Draft Abg 100,000 Heater

1 Answer

I have a RMI-70LP Dyna-Glo 18,000 btu unvented room heater. Can it be converted to natural gas? These can be converted by changing the orface on the heater and also the regulator. Best to contact your

Question about H Series Induced Draft Abg 100,000 Heater

1 Answer

...the flame when it goes on. The biggest reason for this will be small spider webs in the burner orfaces. These are on the main gas manifold where it connects to the burners. You can get a small ...

Question about H Series Pool & Spa Heater 400k Btu Propane Gas Milivolt Ignition H400p1

1 Answer

...on and off but then finally turns off with a miniexplosion sound. This can be plugged or dirty orfaces at the gas header. These are on the pipe and feed gas to the burners. Using a small wrench ...

Question about 10K BTU, Vent Free, 2 Plaque Infrared Space Heater, Natural Gas Infra-Red Patio

1 Answer

lp vent free gas log inserts pilot light wont light Appears to be blowing out, I have a 1/2 inch gas line feed it, could this be a problem. Regulator is rated for 11 inches of w.c. Could need a new ...

Question about 1988 F 150

1 Answer

where is orface tube on 88 f150 where is the orface tube and how to change it It is at the inlet to the AC evaporator core on the passenger side of the firewall under the hood. This would be the small

Question about 2005 Chevrolet Malibu LS

1 Answer

chevy malibu 2005 3.5 a/c orface tube location Location of a/c orface tude Yours has a thermal expansion valve (TXV). no orifice tube . look at fire wall where the a/c pipes go in look for this part .

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

AskDyson
AskDyson

Level 3 Expert

2572 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

73785 Answers

john h

Level 3 Expert

29497 Answers

Are you a Heating & Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...