Questions & Answers for: Cfm how to replace a rcd fuse Home

Question about Daikin R410a Split System Air Conditioner

1 Answer

My air condi is broken I have no idea what is happening, it stopped yesterday suddenly. If you flip the switch with engine idling and hood up do you hear a loud CLICK? That is the clutch which couples

Ad

Question about 802 Ecofan Table

2 Answers

same problem here I have done the testing and just need to replace the thermoelectirc module.... but Caframo won't sell me one. Anyone know where I can et one that works for the same specs? These fans

Ad

the metal strip on the bottom, can it be replaced? I have a Ecofan and the metal strip on the bottom, can it be replaced? The fan isn't turning and the strip is bent. There are no replacement parts ...

Question about Daikin R410a Split System Air Conditioner

1 Answer

...We have had a Daikin air-con guy out 4 times and all he could find was a faulty capacitor so he replaced it and we still have the problem. He checked the compressor and there is no leakage, the ...

Question about Daikin R410a Split System Air Conditioner

1 Answer

...of high pressure switch Condenser coil is dust blocked.-Clean it. Rpm of fan motor is less-Replace capacitor. If over charged gas- release some gas. Check for continuity for high pressure ...

Question about Daikin R410a Split System Air Conditioner

1 Answer

...after been on for 10mins it flashes L1 and cuts off,we have been waiting 4 weeks for Blueline to replace the boards as they said that was the problem since they replaced the boards the L1 still ...

Question about Daikin R410a Split System Air Conditioner

1 Answer

dalkin VRV system air conditioner not cooling Most the time when unit does not get cold,but air is still attempting to blow air, it is because it needs to be cleaned. Sometimes filter or vents are ...

RCD fuse box from my house it starts working again. Then another 45min of use the unit cuts out again which give an error code appears again. Can some please shed some light what the problem could be?

Question about 802 Ecofan Table

1 Answer

Lasko E 20739 does not run http://www.youtube.com/watch?v=ua6F0Ix04CI try this there is a fuse in the box that could off blown.

Question about 802 Ecofan Table

1 Answer

ecofan not working The problem is most likely a bad TEG module or possibly a bad fan motor. The most common problem is a failed TEG module. Caframo will not sell replacement TEG modules as they ...