Question about Laars Lite2 Ld 400,000 Btu Heater
jandy lite2 heater has fl5 error code, all voltages look good all test points have acceptable voltage except will not energize igniter. Power control board is expensivr to replace on a guess. If all ...
Question about Laars LX Pool Heater / 250,000 BTU / Propane Gas
My LX heater will not start blower but I have 230 volt on black and white terminals. When on and off? some turn to auto . make sure is on manual again raise the temp and wait
fl4 code i replace the ignator but the code is still present i want to know if the conversion plug is the problem Thank you for posting your question here on Fixya.com. If you follow the two wires up ...
Question about Lite 2 Natural Gas Pilot Light Heater
...trouble-free. John Never mind, I switched the supply voltage to 115, flipped the conversion plug & changed the igniter. It fired right up. Jandy really blew it on the 230 volt setup of this
how to convert from 230v to 115v This unit has a plug that has multiple jumpers that converts it from 230 to 115. If I were doing it I would call Jandy technical support and let them lead you through ...
my pool heayer will not light i got a f-3 codewitch said main control board i replaced it with a new ro366800 i did check all safty switches befor i did that all are working flow switch closed high ...
Question about Aqualink Pda Ps4 Wireless Handheld Remote Control System Pool and Spa Combo
Set a program for pool mode on Want to turn my pool air bubbler, waterfall and cleaner on for certain times each day. This works when I turn pool mode on with my PDA but I want to program it so it ...
Question about Laars Lite2 Ld 400,000 Btu Heater
what does FL-5 mean on a laars lite2 heater Heater doesn't work, when power is turned on the code fl-5 appears If all voltage test points are within range, then it's 1 of 3 problems: Power Conversion ...
...Model FHPM1.5, s/n: C13JL3266. It has a motor: brand: Century, line: Centurion, Part O-193986-24, type: CX, frame: Y 56 Y, Hz: 60, RPM: 3450, Volts: 230/115, 1081 pool pump duty mount horiz with vent ...
Question about Laars Lite2 Ld 400,000 Btu Heater
Have a jandy lite 2 that burniing out igniter. it's pushing 230 v to the igniter. it's supposed to be 115v. what part is causing that. start on page 17. this should be done by electrician. pump is 230
Usually answered in minutes!
2 Questions