Question about Affinity ATF7000E Front Load Washer

1 Answer

...error. Replace the control board. E97 Console control problem Replace the control board. E98 Console control problem Replace the control board. EB1 Incoming power frequency out of limits. Refer to ...

Ad

Question about GLTF2940ES Front Load Washer

1 Answer

...limits. E95 Communication error. EB1 Incoming power frequency out of limits. EB2 Incoming line voltage above 130 VAC. EB3 Incoming line voltage below 90 VAC. EF1 Clogged drain pump. EF2 To much

Ad

Question about ATF6000ES Front Load Washer

1 Answer

...limits. E95 Communication error. EB1 Incoming power frequency out of limits. EB2 Incoming line voltage above 130 VAC. EB3 Incoming line voltage below 90 VAC. EF1 Clogged drain pump. EF2 Too much

Question about ATF6000ES Front Load Washer

1 Answer

...error E59? depending on the ohms readings you may have to replace the motor or the speed control board board.disconnect the plug from the motor check the resistance on pins 1to 2 1 to 3 then pin 2-3 ...

Question about ATF6000ES Front Load Washer

1 Answer

error code E52 can't find manuel doesn't spin fast bad signal from tacho generator. You have to disconnect the plug from the drive motor and measure the resistance pins 4&5 in the motor. if the ...

Question about AEQ6000ES Electric Dryer

1 Answer

...error code. I got an E68 (button stuck), but suspect that's a red herring because all the functions seem to work (see Function Test Sequence in the following link), although I suppose it may point to ...

Question about FRS3R5EMB Side by Side Refrigerator

3 Answers

...error code on my frigidaire gallery refrigerator. Resetting it was a temporary fix. I replaced the control board ($130) to no avail. I then replaced the evaporator fan and noticed the black rubber ...

Question about GLTF2940ES Front Load Washer

1 Answer

...limits. E95 Communication error. EB1 Incoming power frequency out of limits. EB2 Incoming line voltage above 130 VAC. EB3 Incoming line voltage below 90 VAC. EF1 Clogged drain pump. EF2 Too much