H2-00 means Thermistor open - Open upper heater thermistor or the fusing unit is not installed when the door is closed.
L1-00 Mirror feed problem - make sure the mirror lock is not on or remove
Please click here for the complete list of error code of your printer and how to reset the printer.
Thank you for using Fixya!
If you need further help, reach me via phone at https://www.6ya.com/expert/elixirjose_00375ea24bd8141b
H2 00 code it thermistor is open. Just close it or inspect this section.
From the manual:
H2 00 Content Thermistor open detection
Details Thermistor open detection
Fusing unit not installed
Cause Thermistor defect
Control PWB failure
Fusing section connector contact failure
Fusing unit not installed
Check
and
remedy
Check the harness and the connector of
the thermistor and the MCU.
Clear the display of self-diagnostics with
SIM 14.
Remarks Thermistor open
Please rate and make a comment if you find this solution very helpful and might help others as well. Post more comments if you need more help.
Regards and thank you for using Fixya !
338 views
Usually answered in minutes!
I had reinstalled the Fusing section. But now, how do I get the keys to do anything but beep? I don't see anything on the page for clearing the H2 00. Thanks Dave
I sent a reply. Are you done helping? I already knew the answers you gave me. I want you to be specific on how do I get rid of the H2 00 code!! Thanks Dave
×