Removed my non programable Honeywell RT 5220D replaced it with a Honeywell RTH6350D to run my Goodman Heat Pump. First I labeled the wires then connected wires as follows: AUX, G, C, O/B (orange wire) Y, R Rc. Red wire went into the R terminal with a metal jumper connecting R &Rc. I'm not sure if I need to program the System type to be for Heat/Cool Multiple Stages. Or Heat pum w/backup and Aux heating? Also, the instructions stated if I did not have a wire to both E and AUX terminals take a small piece of wire to connect both. If I need to do this. What is the proper way to do this ?

1 Answer

Anonymous

Level 2:

An expert who has achieved level 2 by getting 100 points

MVP:

An expert that got 5 achievements.

Sergeant:

An expert that has over 500 points.

Governor:

An expert whose answer got voted for 20 times.

  • Expert 192 Answers
  • Posted on Feb 15, 2011
Anonymous
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

MVP:

An expert that got 5 achievements.

Sergeant:

An expert that has over 500 points.

Governor:

An expert whose answer got voted for 20 times.

Joined: Jan 22, 2011
Answers
192
Questions
0
Helped
55504
Points
594

Leave the factory jumper between R & RC. Connect the wires to the new stat just as you have them labeled. Use a piece of thermostat wire to make a jumper from AUX to E terminals. Your new thermostat should give you instructions on how to access the installer set up. You are going to set it up as heat pump with aux. I see this is 2 days old but if you need any help let me know.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

531 views

Ask a Question

Usually answered in minutes!

Top Honeywell Heating & Cooling Experts

Paul Carew

Level 3 Expert

3965 Answers

Cindy Wells

Level 3 Expert

6751 Answers

john h

Level 3 Expert

29497 Answers

Are you a Honeywell Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...