Krups Caffe Bistro 867 Espresso & Coffee Maker Logo
Anonymous Posted on May 08, 2009

Warming plate trips GFI.

After coffee is done as soon as the warming plate clicks on it trips the GFI plug and shut down the plug, hence cold coffee when I get up !!
I love my Krups 867 it has served me well since 1996 not 1 problem until now. Can I fix it or can it be repaired ??

Thanks, Richard

  • 2 more comments 
  • Anonymous May 09, 2009

    No the plug is not a grounded plug,it is only a 2 prong but it's pluged into a gfi outlet.

    I can take it apart so I will look inside to see if there is a leak and I will let you know if this works.



    Thanks, Richard

  • Anonymous May 10, 2009

    I took the bottom off and nothing was wet all looked good.. I cleaned and wiped the inside down all looked good but when I plugged it in and brewed some water all was fine until the warming plate clicked on about 5 minutes later, then the clock flashed once and the it click off ???

  • Anonymous May 11, 2009

    I'm a pretty handy guy,there's not a lot to this thing. When I took the bottom off I did'nt see any black spots or burnt marks I just don't know what to check? If you have a suggestion please share, if I don't think I can do it then I'll take it in somewhere. If nothing else I can disconect the warming plate.





    Thanks, Richard

  • Anonymous May 11, 2010



    There is a short to ground in the warming plate circuit. Most likely just wet. If you can take it apart, dry it out (rag, hairdryer) and check for internal leaks which may be getting that area wet. It may just have been a one-time spill which caused it.



    The question is how is the coffee maker grounding.

    Does the power cord have a gounding plug (3-prong) on it?

×

1 Answer

Anonymous

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

President:

An expert whose answer got voted for 500 times.

  • Master 1,489 Answers
  • Posted on May 10, 2009
Anonymous
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

President:

An expert whose answer got voted for 500 times.

Joined: Apr 19, 2009
Answers
1489
Questions
7
Helped
781122
Points
4966

Well, it's still a short to ground. But sounds like it's not simple. Needs to go to the shop, unless you want to try your hand at it.

Charlie

  • Anonymous May 11, 2009

    You most likely wouldn't have any burn marks -- a GFI is so sensitive and quick, it doesn't allow time for anything to get hot enough to scorch.



    I'm just brainstorming here.



    Maybe there's corrosion on a circuit board which you could clean.



    Or maybe the thermostat and/or relay which controls the warming plate has burned contacts which causes enough arcing to trip the GFI -- these contacts are probably not visible, they'd be inside the devices.



    If you can access the contacts, sandpaper/emery board and electrical contact cleaner might do the job.



    all for now...

×

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

187 views

Ask a Question

Usually answered in minutes!

Top Krups Coffee Makers & Espresso Machines Experts

Paul Carew

Level 3 Expert

3965 Answers

Sudeep Chatterjee
Sudeep Chatterjee

Level 3 Expert

3269 Answers

Grand Canyon Tech
Grand Canyon Tech

Level 3 Expert

3869 Answers

Are you a Krups Coffee Maker and Espresso Machine Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...